Authorities' findings and the test laboratory: the brief that turns an inspection into a gap analysis

After a DGCCRF or DDPP inspection, the brief that sets up the laboratory gap analysis: table of findings, written questions, NDA, costs and time frames.

Authorities' findings and the test laboratory: the brief that turns an inspection into a gap analysis

After an inspection by the DGCCRF or a departmental DDPP on electrical appliances, a company often has to complete its compliance file and turns to a test laboratory to review the reports it holds. Before starting, the laboratory frequently asks for a complete description of what the authorities have found. The request is legitimate: a laboratory can only give a useful answer if it knows which requirements are at stake, for which models, and what is expected of it.

The brief on the authorities' findings answers that request. Drafted by the lawyer from the authorities' own documents only, it restates each finding, records what has already been done and puts precise questions to the laboratory. It allows the laboratory to deliver a gap analysis: for each requirement, what is demonstrated, what is missing and what must be corrected. Without it, the company may receive a general report that is technically sound but answers none of the findings.

We start from a fictitious example, then describe the method step by step, with the usual time frames and costs. This article complements our page on regulatory compliance reviews.

The case: a desk lamp brand (fictitious example)

Take a desk lamp brand (fictitious example). Before launching its review, the selected laboratory asks for an exhaustive note of the authorities' complaints. The lawyer drafts it: chronology, products concerned, roles, then a table of findings showing, for each one, the provision relied on, the finding, what has been done and what is expected of the laboratory.

The aim is to establish the gaps, then to correct them at the factory so as to give the authorities assurances. The brief therefore serves twice: first to direct the laboratory's work, then to let the company link each correction to an identified finding when it reports back to the authorities.

What the rules require of the brand, and what the laboratory can bring

Obligations under Decree No. 2015-1083

Electrical equipment operating at a voltage between 50 and 1,000 volts AC, or between 75 and 1,500 volts DC, in principle falls under French Decree No. 2015-1083 of 27 August 2015, which transposes the Low Voltage Directive 2014/35/EU. Most small mains-powered appliances, such as desk lamps or fans, fall within this scope. The decree defines the manufacturer as the person who manufactures electrical equipment, or has it designed or manufactured, and markets it under its own name or trademark (Article 2, 3°).

Under Article 4, the manufacturer draws up the technical documentation described in Annex III, carries out the conformity assessment procedure and, once compliance with the safety objectives has been demonstrated, draws up the EU declaration of conformity and affixes the CE marking (2°); it also indicates its name and postal address on the equipment or, failing that, on the packaging or an accompanying document (6°). The importer checks that these steps have been taken and indicates its own name and postal address (Article 6, 2° and 3°).

Under Article 13, the EU declaration of conformity states that compliance with the safety objectives has been demonstrated, and by drawing it up the manufacturer assumes responsibility for the conformity of the equipment. Annex III lists the content of the technical documentation, including the list of harmonised standards applied and the test reports.

What the laboratory does, and what it does not do

The laboratory can say whether an existing report covers a model, which tests are missing, whether the editions of the standards used are still relevant, and whether the critical components listed match those fitted. It does not rule on whether a finding is legally well founded, it does not reply to the authorities and it does not sign the EU declaration of conformity, which remains the manufacturer's responsibility. The brief bridges the two worlds: it turns findings expressed in legal terms into technical questions an engineer can answer.

Step 1 - Copy the findings word for word

The first rule is to copy each finding exactly as it appears in the authorities' documents: request for documents, summons, letters. Each finding is quoted, with the reference and date of the document. Rewording a complaint, even to clarify it, can change its scope, and the laboratory might then answer a question the authorities never asked. Where the findings stem from a request for documents, see our guide on the DGCCRF request for documents under Article L. 512-8.

The brief adds no finding and does not point the laboratory to matters outside the scope of the inspection. The laboratory is engaged to address the findings; extending its task to the whole business lengthens the timetable and raises the cost.

Step 2 - Chronology, products concerned and roles

Before the table, the brief sets out the file under three short headings.

  • Chronology: the dates of the inspection, of the authorities' requests and letters, of the company's replies and, above all, of any deadlines already announced, so that the laboratory knows from the outset when its deliverable is due.
  • Products concerned: the list of models and references as the authorities name them, with the matching commercial references where they differ, since a reference left out at this stage will be missing from the gap analysis.
  • Roles: who appears as manufacturer, importer or distributor on the rating plates, packaging, invoices and the authorities' documents, and who actually manufactures, described as they appear without any legal characterisation.

Where the characterisation of a company raises a question, it is a matter for the lawyer's analysis and has no place in a document given to a laboratory.

Step 3 - The four-column table of findings

The core of the brief is a table with four columns for each finding: the provision relied on by the authorities, the finding copied word for word, what has been done since, with the date, and the question put to the laboratory. The last column tells the laboratory exactly what is expected of it, finding by finding.

Not every finding calls for the same answer. Some are corrected on paper: manufacturer and importer details on the plate or packaging, batch number, warnings in the instructions. For these, the "what has been done" column refers to the corrected mock-ups, and the question may be limited to a check against the marking and instruction clauses of the standard, or read "not applicable". Others, such as a missing declaration of conformity or technical documentation, require a prior technical review: this is where the laboratory is needed.

Where a finding seems to cite the wrong provision, the brief reproduces it as written with a neutral note such as "provision to be checked", without drawing any argument from it. Whether to raise the error with the authorities is decided later, with the lawyer, since a finding citing the wrong text may still match an obligation under another text.

Table 1 - Template table of findings (to be completed)

Provision relied on Authorities' finding What has been done Question put to the laboratory
How to fill in: the provision as cited by the authorities (article, paragraph), with the note "provision to be checked" if needed, without comment How to fill in: the finding copied word for word, in quotation marks, with the document and its date How to fill in: the measure taken and its date (sales suspended, corrected mock-ups, request to the factory), or "nothing to date" How to fill in: the precise question, with a model-by-model answer expected, or "not applicable" for a purely documentary finding
Finding 1:
Finding 2:
Add one row per finding, in the order of the authorities' documents, without adding or removing any.

Step 4 - Isolate the central technical point and ask for a model-by-model answer

In most files, several findings depend on a single technical question, for example whether tests performed on one model demonstrate the conformity of the other models in a range, or whether older reports can still be used. Until that question is settled, neither the technical documentation nor the declaration can be drawn up. The brief should isolate it and state it clearly at the top of the questions.

The answer must be requested model by model. A global conclusion such as "the range may be declared compliant subject to additional tests" does not allow the company to draw up a declaration identifying the equipment concerned, to know what to correct at the factory, or to reply to the authorities reference by reference. How this point is framed, and how it fits with what has already been said to the authorities, depends on each file; it is one of the stages where the lawyer's input weighs most on what follows.

Step 5 - Put the technical questions in writing

Questions to the laboratory are set out in writing in the brief. A written answer can be used in the technical documentation and, if the company so decides, produced to the authorities. In practice, around seven questions cover most needs.

Table 2 - Checklist of written questions to the laboratory

No. Written question to the laboratory Why ask it Expected answer
1 Which harmonised standard, general part and particular part, applies to each model, and why? The choice of standard drives every test Reference of each part, model by model
2 Which editions were applied in the existing reports, which are current, and do the differences change the conclusions? The declaration cites the editions actually applied Table of differences between editions, clause by clause
3 Do the tests performed cover each variant, and on what conditions? The declaration must identify the equipment it covers Covered, covered with reservations or not covered, for each model
4 Does the list of critical components in the reports match the components fitted, and are their certificates valid? A changed component or expired certificate can weaken a report Validated list or gaps identified
5 Can reports issued in the factory's name be used in the brand's technical documentation, and what must be added? The documentation must demonstrate the conformity of the product sold under the brand Reasoned opinion and list of additions
6 In what form (written report, table per model, language) and by what date will the deliverable be provided? The date must fit the deadlines announced to the authorities Written commitment on form and date
7 Will other teams be involved (substances, environment, endurance), on what scope and at what price? Avoid an amendment discovered mid-assignment Separate quote before any commitment

Step 6 - Control how the brief is transmitted

The brief contains sensitive information: the existence of an inspection, the findings, the commitments made. It is sent only once a non-disclosure agreement expressly covering it has been signed. Points to check include the company named as party, oral exchanges, the persons allowed to receive the information (advisers, factory, suppliers) and the right to show the report to the authorities and distributors. The offer and purchase order are issued in the name of the company that places the product on the market.

The brief copies the findings but attaches no document from the criminal procedure, whether an official report, a summons to an interview or an interview record. The laboratory does not need them, and they are not meant to circulate beyond the defence. Technical documents (reports, drawings, photos, mock-ups) are attached, since those are what the laboratory must examine.

Step 7 - Get any additional work priced before committing

When the review starts, the laboratory may announce that other teams will be involved: substances (RoHS, REACH), environment, electromagnetic compatibility, or endurance testing. These may prove useful, but they should not be ordered without a written scope, a price, a time frame and a statement of what is included in the original offer or requires an amendment. The decision is preferably taken after the documentary review. As an order of magnitude, a full substance analysis costs around 1,500 to 2,000 euros excluding VAT, over 3 to 5 weeks.

Time frames and costs: orders of magnitude

The following figures are orders of magnitude taken from laboratory offers; they vary with the product, the number of models and the laboratory.

  • Documentary review of existing reports by an accredited laboratory: 1,500 to 7,000 euros excluding VAT, over 2 to 12 weeks depending on the laboratory.
  • Full testing: 10,000 to 25,000 euros excluding VAT, over 6 to 10 weeks, with any endurance test priced separately.
  • Electromagnetic compatibility alone: 1,500 to 5,000 euros.

In a typical timetable, the order is placed between D+7 and D+30 and the gap analysis delivered between D+30 and D+60, followed by any additional tests, then the technical documentation and the declaration (orders of magnitude). The brief is prepared while laboratories are consulted, so the review can start as soon as the order is placed. If the laboratory's delivery date makes a deadline announced to the authorities impossible to meet, it is advisable to inform them before the deadline, giving the reason, the order placed and a realistic new date.

Documents needed to draft the brief

The table below shows, for each document, what the brief takes from it and whether it is attached.

Table 3 - Documents: what the brief takes, what is attached

Document What the brief takes from it Attached to the brief?
Authorities' request for documents Findings and provisions relied on, word for word, with the date No, quoted
Summons to an interview Subject and provisions relied on, if stated No
Letters from the authorities Findings and deadlines set No, quoted
Company's replies and commitments Measures announced and dates promised (chronology) No, summarised
Official reports and other criminal procedure documents Nothing beyond the findings already copied No
Existing test reports Model tested, standards and editions, date, report holder Yes
List of models and commercial references Correspondence with the models concerned Yes
Drawings, diagrams, bill of materials, internal photos General description of the product Yes, if available
Current and corrected rating plates, packaging and instructions Corrections made ("what has been done" column) Yes
Critical component certificates, existing declaration and documentation State of the file on the date of the brief Yes, if available

Before sending, a final check avoids most queries from the laboratory:

  • The non-disclosure agreement is signed and expressly covers the brief.
  • The offer and purchase order are in the name of the company placing the product on the market.
  • Each finding is copied word for word, with its source and date.
  • No document from the criminal procedure is attached.
  • The list of models is complete and matched with the commercial references.
  • The expected delivery date fits the deadlines announced to the authorities.

After the laboratory's answer: from gaps to assurances for the authorities

The laboratory's answer lists the gaps model by model; they are then dealt with at the factory. The technical documentation and the EU declaration of conformity are drawn up in the brand's name, at their actual date, once the laboratory's conclusions are known; the official EU portal Your Europe notes that the declaration is signed only after the conformity assessment and once all the technical documentation has been compiled. Towards the authorities, the brief allows each measure to be presented against the finding it addresses: what has been done, what is under way and the timetable for the rest. Such a presentation shows that each finding has been examined and dealt with; it does not prejudge the outcome of the procedure.

How the firm can help

Guillaume Leclerc assists companies under inspection in reading the findings, drafting the brief and the written questions, negotiating the non-disclosure agreement and the laboratory's terms, and following the review through to the gap analysis. The firm then prepares the framework for the technical documentation and the declaration, and the reply to the authorities with a realistic timetable. The laboratory invoices the company directly.

Frequently asked questions

Should the official report be sent to the laboratory?

We advise against it. The brief copies the relevant findings word for word, which is enough for the laboratory, and documents from the criminal procedure are not meant to circulate beyond the defence. Only technical documents are sent, under a non-disclosure agreement.

Can the laboratory reply to the authorities on the company's behalf?

No. The laboratory gives a technical opinion on the product's conformity. It does not decide whether a finding is well founded and does not reply to the authorities. The EU declaration of conformity is drawn up by the manufacturer, which thereby assumes responsibility for conformity (Decree No. 2015-1083, Article 13). The laboratory's report is a document the company may produce in support of its own reply.

Who pays for additional work by the laboratory?

The company that places the order, since the laboratory invoices it directly. Any additional workstream (substances, environment, endurance testing) should therefore be priced in writing before it is ordered.

Conclusion

The brief handed to the laboratory is short, but it determines the quality of the gap analysis and lets the company correct at the factory and report to the authorities finding by finding.

If your company has just been inspected on electrical products and needs a laboratory to work on the findings, Guillaume Leclerc can draft the brief, frame the exchanges with the laboratory and prepare the reply to the authorities; see our page lawyer for DGCCRF and DDPP inspections in France.

Guillaume Leclerc, avocat at the Paris Bar, Victoris law firm, 34 avenue des Champs-Élysées, Paris.

Further reading: